STANDARD TEST METHOD |
CONBLOCK CDA RED RESULTS VS. REFERENCE |
CRD-C48 Permeability of Concrete |
Coefficient of permeability rating (K)=1.3x 1013 (96% reduction, 21 days |
ASTM C39 Compressive Strength of Concrete |
25% increase after 1 days; > 10% increase after 28 days |
ASTM C1585 Measurement of Rate of Absorption of Water by Hydraulic Cement Concretes |
36% reduction after 90 days |
ASTM C157 Length Change of Hardened Hydraulic-Cement Mortar and Concrete |
Dry shrinkage of 0.013% (130 microstrain) after 56 days; 70% less than reference |
ASTM C1567 Determining the Potential Alkali-Silica Reactivity of Cementitious Materials and Aggregate |
10% reduction after 28 days |
ASTM C1260 Determining the Potential Alkali-Silica Reactivity of Aggregates |
18% reduction after 28 days |
ASTM C1760 Bulk Electrical Conductivity of Hardened Concrete |
15% reduction at 1000 Hz |
BS EN 12390-8 Depth of Water Penetration under Pressure |
36% reduction after 90 days |