ConSeal CS-1800
Solvent Free, Waterproofing Membrane
- Finish: Semi-Gloss, Elastomeric Rubber
- Colors: Black, Dark Grey, and White
- Solvent & Isocyanate Free, 100% Solids, Will Not Shrink
- California Proposition 65 compliant
- No degradation in 0.5 pH sulfuric acid immersion per – (ASTM C1898)
- Meets ASTM C836 Requirements
- 50 ft2/gallon coverage per 30 mils coat
FREE Ground Shipping available for orders over $150!
Orders typically ship in 1-business day or less (M-F)!
For bulk order or concrete producer pricing, Contact Us.
$166.32
CS-1800 Solvent Free, Waterproofing Membrane
ConSeal CS-1800 Waterproofing Membrane for use on concrete structures, including foundations, box culverts, manhole risers, lift stations, septic tanks, utility vaults, burial vaults, vertical panel structures, bunker silos, concrete structure patching, and grouting. Additional uses include some metal, fiberglass, and plastic applications. Not intended for expansion joints or joints that move.
PERFORMANCE PROPERTIES
- Finish: Semi-Gloss, Elastomeric Rubber
- Colors: Black, Dark Grey, and White
- Solvent & Isocyanate Free, 100% Solids, Will Not Shrink
- California Proposition 65 compliant
- No degradation in 0.5 pH sulfuric acid immersion per – (ASTM C1898)
- Meets ASTM C836 Requirements
- Positive waterproofing capabilities up to 100 psi – (ASTM D5385)
- Thermal shock resistant, elastomeric rubber membrane.
- Can be applied with brush, roller, trowel, sprayer or squeegee.
- Tack free in less than 90 minutes. Paintable.
- Can be used in confined spaces without respiratory protection. See Safety Data Sheet (SDS) for details.
- Indoor/outdoor application
- Superior Adhesion to most construction materials, including: Concrete, Metal, Fiberglass, Plastic, PVC, Glass, Aluminum, and Wood.
- Passes Severe Wastewater Analysis Testing (SWAT) – ASTM G210-13 (23)
PHYSICAL PROPERTIES
Property |
CS-1800 Value |
Test Method |
Cure System | Hybrid, Moisture Cure | |
VOC Content | 14.2 grams/liter | |
Viscosity | 210,000 – 390,000 centapoise | |
Cure Rate | 1/8” every 24 hours (77°F at 50% Relative Humidity) | |
Coverage Rate | 50 ft2/gallon per 30 mils coat |
PERFORMANCE CHARACTERISTICS
Property |
CS-1800 Value |
Test Method |
Shear Strength | 132 psi | ASTM D1002 |
Tensile Strength | 113 psi | ASTM D412 |
Elongation | 535% | ASTM D412 |
Adhesion to Concrete (Clean, Dry) | 33 pli, cohesive failure | ASTM C794 |
Shore OO, Hardness | 67 | ASTM C2240 |
Shrinkage | No measurable shrinkage after 14 days | |
Service Temperature | -40°F to 225°F (-40°C to 104°C), continuous service | |
Application Ambient Temperature | 40°F to 130°F (4°C to 55°C) | |
Application Surface Temperature | 40°F to 130°F (4°C to 55°C) |
APPROXIMATE CURING SCHEDULE
Surface Temp. & 50% Relative Humidity |
Dry to Touch |
Min. Recoat Time |
Service Ready |
50°F (10°C) | 90 Minutes | 5 Hours | 72 Hours |
75°F (24°C) | 90 Minutes | 4 Hours | 72 Hours |
90°F (32°C) | 90 Minutes | 4 Hours | 72 Hours |
Curing schedule based on 40 mils applied to clean, dry concrete.
Consider strength of skin layer prior to recoating.
FREE Ground Shipping available for orders over $150!
DIRECTIONS FOR USE
Surface Preparation
Concrete: Surface must be free of form release, curing compounds, sealers, loose debris or other contaminants. Sand blasting, power washing, wire brushing, or other appropriate cleaning techniques can be utilized. Dry all visible and standing water prior to applying CS-1800. Make sure the surface is free of frost.
Metal: Surface must be free of loose debris or other contaminants. Sand blasting, power washing, wire brushing, or other appropriate cleaning techniques can be utilized. Dry all visible and standing water prior to applying CS-1800.
Fiberglass/Plastic: Surface must be free of form release, loose debris or other contaminants. Sand blasting, power washing, wire brushing, or other appropriate cleaning techniques can be utilized. Dry all visible and standing water prior to applying CS-1800.
DO NOT USE petroleum solvents such as Mineral Spirits or Xylene for surface preparation.
Priming: For applications with continuous water immersion ConSeal recommends using a surface primer. ConSeal CS-80 and ConSeal CS-85 are specifically designed for ConSeal’s elastomeric sealants.
Application Instructions: Maintain CS-1800 at room temperature (~70°F) before applying to ensure easy application. Utilizing a brush, roller, trowel, or squeegee; apply CS-1800 onto the prepared surface at the desired millage. Spread rate: 50 sq. ft./gal. per 30 mils coat (nominal). If a second coat is necessary, apply as soon as possible. When recoating ensure the skin layer is clean, dry, and has met curing requirements.
Packaging & Storage: Available in 2-gallon pails – 56 pails per pallet. 12-month shelf life from manufacture date when stored in a cool, dry area. Elevated temperatures > 100°F may reduce shelf life. Shelf life after opening is 6-month maximum, less manufacture shelf life. Remove top skin layer. Product consistency may thicken.