Toll Free: 1.800.332.7325
Local/Global: 1.937.845.8776
Email  Contact

Cold Weather Installation


PROJECT LOCATION:

United States, Toledo, Ohio

DATE:

January, 1995

THE SITUATION:

The sealing of precast concrete in northern states is made tricky during the winter due to cold temperatures. A watertight joint is still required for installation, but providing that quality becomes more difficult; therefore, in this installation of precast concrete elliptical pipe it required a sealant that can provide the watertight quality during cold installation.

THE SOLUTION:

CS-202 was used because it compresses more than other sealants in cold weather installations and provides the same watertight qualities as other ConSeal products meeting the ASTM C-990 Standard - a simple solution with a quality product.

Sealant Application:

  • Elliptical Concrete Pipe

ConSeal Products Used:

Applicable Industry Standards:

  • ASTM C-990